CPE & Access Gateway Products MP-202 Bedienungsanleitung Seite 9

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 12
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 8
Application Note 3. DSP Packet Recording
Version 2.6.1 9 June 2008
Note: The packet recording captures are still active when the TDM and or
network packet recording are activated.
¾ To activate the TDM input recording:
1. If the packet recording tool is already activated, use the same command for packet
recording (otherwise, skip to Step 2):
Gateway> dsp_cmd pr 0 1 10 16 2 4
2. If the packet recording tool is not activated, perform the following:
a. Perform steps 1 through 3 for packet recording in Section 3 on page 7.
b. Run the dsp_cmd pr command again.
Figure 3-3: Wireshark Capture with TDM Recording and Packet Recording
¾ To activate both TDM input and network recording:
1. If the packet recording tool is already activated, enter the packet recording command
twice, as shown below (otherwise, skip to Step 2):
Gateway> dsp_cmd pr 0 1 10 16 2 4
Gateway> dsp_cmd pr 0 1 10 16 2 4
2. If the packet recording tool is not activated, perform the following:
a. Perform steps 1 through 3 for packet recording in Section 3 on page 7.
b. Run the dsp_cmd pr command twice.
¾ To activate RTP recording:
1. If the packet recording tool is already activated, use the same command three more
times (otherwise, skip to Step 2):
Gateway> dsp_cmd pr 0 1 10 16 2 4
Gateway> dsp_cmd pr 0 1 10 16 2 4
Gateway> dsp_cmd pr 0 1 10 16 2 4
2. If the packet recording tool is not activated, perform the following:
a. Perform steps 1 through 3 for packet recording in Section 3 on page 7.
b. Run the dsp_cmd pr command three times.